The LUBRICUS M lubrication system is optionally equipped with up to five pump bodies (P1, P2, P3, P4, P5). The double piston pump bodies each have two outlets, are operated alternately and provide the same quantities of lubricant.

LUBRICUS M can work either in time mode or in pulse mode (PLC).

In time mode, the internal controls monitor both the amount of lubricant and the time intervals between lubrications..

In pulse mode, the desired lubrication intervals are performed by programming the PLC. Regardless of the selected mode, each pump body can be controlled separately.

Lubricus M
 

Product features LUBRICUS M

  • Time control OR pulse control
  • Supply pressure up to 70 bar
  • Error/empty message shown on display
  • Operating temperature -20°C up to +70°C
  • System monitoring & feedback function
  • Separate control of each pump body
  • Simple operation / PIN protected
  • Supplies grease up to NLGI class 2
Downloads LUBRICUS M
Datasheet:
Deutsch | English | Polisch | Português Brasileiro | Español
 

Operating Instructions:
Deutsch | English | Polisch | Português Brasileiro | Español
 
 

LUBRICUS M - Direct lubrication

The Lubricus M can be equipped with up to five pump bodies, meaning it can automatically supply up to ten lubrication points with ease.
With hose lengths of up to 5m, many lubrication points can be reached directly.

Benefit of direct lubrication with LUBRICUS M:
  • Short grease lines
  • No complex pipework
  • One piston (twin pump) per lubrication point
  • No distributors required
  • Simple retrofit solution
  • Preventive monitoring of lubrication points
  • Measurement of back pressure for each lubrication point
Lubricus M

 

LUBRICUS M - Monitored and safe supply of lubrication points
 

Technical Data LUBRICUS M

Functional principle:
Operating voltage:
Operating pressure:
Lubrication volume:

Min. dose volume:
Outlets:
Connection:
Operating temperature:
Weight:
Dimensions, max.:
Connector:
Level monitoring:
Pressure monitoring:
Integrated controller:
piston pump
24VDC
max. 70 bar
1500 cm3 with grease
2000 ml with oil
0,15 cm3 (per outlet)
2, 4, 6, 8 or 10
6/4mm tube
-20°C up to +70ºC
approx. 4.000g
WxHxD 162 x 255 x 165mm
M12x1, 4-pole
integrated, dry reed contact
integrated, electronic
microelectronic
Lubricus M